6630 POLYESTER-FIBER PAPER/POLYESTER FILM/POLYESTER-FIBER PAPER

 (CLASS-B to CLASS-F)

    The composition of the TRIPLEX-P consists of two Layers of POLYESTRR-FIBRE PAPER and a single layer of POLYESTER FILM in the center, which is suitable for Class B insulation. The POLYESTER-FIBER PAPER Covering the outer layer, gives a good protection to the POLYES FILM from mechanical abuse and permiting the absorption of any insulation varnish which is not possible with POLYESTER FILM individually. TRIPEX-P can also be used in the Class F insulation if it is impergnated in the Class F resins.

Triplex-p (class B)

TECHNICAL SPECIFICATION

Properties

Unit

Value

Thickness

Nominal thickness

mm

0.15

0.20

0.25

0.30

0.35

0.40

Mean tolerance

±0.03

±0.04

±0.04

±0.05

±0.05

±0.05

Min. tensile force

Lengthwise

kgf

16

Crosswise

16

Min.volume resistivity

At room temp.

Ω·m

1.0X1011

Water absorption

1.0X1010

130

1.0X1010

Min.breakdown voltage

At room temp.

kV

9

After bending at 180

8

130±2

8

Water absorption

7

Triplex-p (class F)

TECHNICAL SPECIFICATION

Properties

Unit

Value

Thickness

Nominal thickness

mm

0.20

0.25

0.30

0.35

0.40

Mean tolerance

±0.03

±0.04

±0.05

±0.05

±0.05

Min. tensile force

Lengthwise

kgf

18

Crosswise

15

Min. volume resistivity

At room temp.

Ω·m

1.0X1011

Water absorption

1.0X109

155

1.0X109

Min. breakdown voltage

kV

8.0

9.0

10.0

10.0

12.0