SBELB/130  Double glassfiber covered rectangular aluminium wire

Description

Type

Standard

Size Available

Thermal

Classification

Characteristics  and Applications

Double glass fibre covered reclangular aluminium wire with temperature index 130

SBELB/130

GB7672,4/87

a: 0.8-5.60

b: 2.0-16.0

B

With excellent corona-resisting, withstanding of over-loading, etc. They are suited to be windings or coils of various motors and electrical appliances with long-term operating temperature of 130

 

Item

Parameters

Size of conductors

Size of rectangular conductor (mm)

Tolerance of conductor (mm)

a (b) 3.15

3.15a (b) 6.30

6.30b 12.50

12.50b16.0

±0.03

±0.05

±0.07

±0.10

Insulation thickness

Type

Size of rectangular conductor (mm)

Insulation thickness (mm)

SBELB

a: 0.80-5.60

b: 2.00-16.00

0.30 (0.24-0.30)

0.35 (0.28-0.35)

0.40 (0.32-0.40)

0.50 (0.40-0.50)

Electrical properly

SBELB

Insulation thickness(mm)

Breakdown voltage  (V)

0.30

0.35

0.40

0.50

400

500

500

550

Elongation:

17%