YSERIES  THREE-PHASE  INDUCTION  MOTORS

Protection type:IP 44      Insulation class:B

                        Cooling type:IC0141      Rated frequency:50Hz

PERFORMANCE  SPECIFICATIONS

Model

HP

Output

KW

Current

(A)

Voltage

(V)

Speed

(r.p.m)

Eff

(%)

Power factor

Locked rotor torque

Rated torque

Locked rotor current

Rated current

Pull-out torque

Rated torque

Y801-2

1

0.75

1.8

380

2830

75

0.84

2.2

6.5

2.3

Y801-2

1.5

1.1

2.5

380

2830

77

0.86

2.2

7

2.3

Y90S-2

2

1.5

3.4

380

2840

78

0.85

2.2

7

2.3

Y90L-2

3

2.2

4.8

380

2840

80.5

0.86

2.2

7

2.3

Y100L-2

4

3

6.4

380

2870

82

0.87

2.2

7

2.3

Y112M-2

5.5

4

8.2

380

2890

85.5

0.87

2.2

7

2.3

Y13S1-2

7.5

5.5

11.1

380

2900

85

0.88

2.0

7

2.3

Y132S2-2

10

7.5

15.0

380

2900

86.2

0.88

2.0

7

2.3

Y160M1-2

15

11

21.8

380

2930

87.2

0.88

2.0

7.0

2.2

Y160M2-2

20

15

29.4

380

2930

88.2

0.88

2.0

7.0

2.2

Y160L-2

25

18.5

35.5

380

2930

89

0.89

2.0

7.0

2.2

Y180M-2

30

22

42.2

380

2940

89

0.89

2.0

7.0

2.2

Y200L1-2

40

30

56.9

380

2950

90

0.89

2.0

7.0

2.2

Y200L2-2

50

37

69.8

380

2950

90.5

0.89

2.0

7.0

2.2

Y801-4

0.75

0.55

1.5

380

1390

73

0.76

2.4

6

2.3

Y802-4

1

0.75

2.0

380

1390

74.5

0.76

2.3

6

2.3

Y90S-4

1.5

1.1

2.8

380

1400

78

0.78

2.3

6.5

2.3

Y90L-4

2

1.5

3.7

380

1400

79

0.79

2.3

6.5

2.3

Y100L1-4

3

2.2

5.0

380

1430

81

0.82

2.2

7

2.3

Y100L2-4

4

3

6.8

380

1430

82.5

0.81

2.2

7

2.3

Y112M-4

5.5

4

8.8

380

1440

84.5

0.82

2.2

7

2.3

Y132S-4

7.5

5.5

11.7

380

1440

85.5

0.84

2.2

7

2.3

Y132M-4

10

7.5

15.4

380

1440

87

0.85

2.2

7

2.3

Y160M-4

15

11

22.6

380

1460

88

0.84

2.2

7.0

2.2

Y160L-4

20

15

30.3

380

1460

88.5

0.85

2.2

7.0

2.2

Y180M-4

25

18.5

35.9

380

1470

91

0.86

2.0

7.0

2.2

Y180L-4

30

22

42.5

380

1470

91.5

0.86

2.0

7.0

2.2

Y200L-4

40

30

56.8

380

1470

92.2

0.87

2.0

7.0

2.2

Y225S-4

50

37

69.8

380

1480

91.8

0.87

1.9

7

2.2

Y225M-4

60

55

84.2

380

1480

92.3

0.88

1.9

7

2.2

Y90S-6

1

0.75

2.3

380

910

72.5

0.70

2.0

5.5

2.2

Y90L-6

1.5

1.1

3.2

380

910

73.5

0.72

2.0

5.5

2.2

Y100L-6

2

1.5

4.0

380

940

77.5

0.74

2.0

6

2.2

Y112M-6

3

2.2

5.6

380

940

80.5

0.74

2.2

6

2.2

Y132S-6

4

3

7.3

380

960

83

0.76

2.0

6.5

2.2

Y132M1-6

5.5

4

9.4

380

960

84

0.77

2.0

6.5

2.2

Y132M2-6

7.5

5.5

12.6

380

960

85.3

0.78

2.0

6.5

2.2

Y160M-6

10

7.5

17.0

380

970

86

0.78

2.0

6.5

2.0

Y160L-6

15

11

24.6

380

970

87

0.78

2.0

6.5

2.0

Y180L-6

20

15

31.6

380

970

89.5

0.81

1.8

6.5

2.0

Y200L1-6

25

18.5

37.7

380

970

89.8

0.83

1.8

6.5

2.0

Y200L2-6

30

22

44.6

380

970

90.2

0.83

1.8

6.5

2.0

 

SERIES  THREE-PHASE  INDUCTION  MOTORS

 
Overall & Installation Dimensions:

Frame Size

 Mounting dimenssionss

Overall dimensions

A

B

C

D

E

F

G

H

K

M

N

P

R

S

T

AB

AC

AD

HD

HF

L

 

Y80

125

100

50

19

40

6

15.5

80

10

165

130

200

0

12

3.5

165

175

150

175

185

290

 

Y90S

140

100

56

24

50

8

20

90

10

165

130

200

0

12

3.5

180

195

160

195

195

315

 

Y90L

140

125

56

24

50

8

20

90

10

165

130

200

0

12

3.5

180

195

160

195

195

340

 

Y100L

160

140

70

28

60

8

24

100

12

215

180

250

0

15

4

205

215

180

245

245

380

 

Y112M

190

140

70

28

60

8

24

112

12

215

180

250

0

15

4

245

240

190

265

265

400

 

Y132S

216

140

89

38

80

10

33

132

12

265

230

300

0

15

4

280

275

210

315

315

470

 

Y132M

216

178

89

38

80

10

33

132

12

265

230

300

0

15

4

280

275

210

315

315

515

 

Y160M

245

210

108

42

110

12

37

160

15

300

250

350

0

19

5

325

325

255

385

385

600

 

Y160L

254

254

108

42

110

12

37

160

15

300

250

350

0

15

5

325

325

255

385

385

645

 

Y180M

279

241

121

48

110

14

42.5

180

15

300

250

350

0

19

5

355

360

285

430

430

670

 

Y180L

279

279

121

48

110

14

42.5

180

15

300

250

350

0

19

5

355

360

285

430

430

710

 

Y200L

318

305

133

55

110

16

49

200

19

350

300

400

0

19

5

395

400

310

475

475

775

 

    Y series motor is totally enclosed and fan-cooled,three-phase squirrel cage induction motor,that is newly designed in conformity with the relevant requirements of IEC standards.

    Y series motors have outstanding performance,such as high efficiency,energy-saving ,high starting torque ,low noise,little vibrabion,reliable operation and easy maintenance,etc.

    Y series motors are widey used in places,where not exists combustible,explosive or corrosive gas,and without any special requirements,such as machine tools,pumps,fans,transport manchinery ,mixer ,agriculture machinery and food machines,etc.

 

 

SERIES HEAVY-DUTY SINGLE-PHASE

CAPACITOR STARTING INDUCTION MOTORS

 

YC series heavy-duty single-phase motors are suitable for powering small type machine tools and water pumps,specially for family workshops where only-single-phase current supply is available.Motors of the said series are integrated with up-to date design,built with the best quality materials and possess the features of pleasant-looking appearance,outstanding performance,easy maintenace and reliable running.The designations,signs and nominal values are all in conformity with I.E.C.standards.

   YC series protected motors are of IP44 totally enclosed fan-cooling type,rated output is 3HP or below with capacitor starting.Under rated voltage and 50HZ,the starting torque is three times more than the rated torque and 60HZ is more than 2.75times.Motors for 4HP or over are of capacitor start and runtype.They all concentrate the advantages of high starting torque,smooth tunning,low temperature rise,low noise and greater overload performance.

   The rated frequency of the motor is 50~60Hz,and the rated voltage is 200~220V,we can also offer various voluatge under 500V according to customer¡¯s requirment.

PERFORMANCE  SPECIFICATIONS

Model

Power rating

Current

(A)

Starting torque

Rated torque

Starting current

Rated current

Speed

(r.p.m)

HP

KW

YC80a-2

1/2

0.370

3.5

3

6.5

2840

YC80b-2

3/4

0.550

4.9

3

6.5

2860

YC80c-2

1

0.750

5.1

3

6.5

2880

YC90s-2

1.5

1.1

8.83

3

7.0

2900

YC90L-2

2

1.5

11.4

3

7.0

2920

YC100L-2

3

2.2

16.5

3

7.0

2940

YC80a-4

1/3

0.250

3.2

3

6

1410

YC80b-4

1/2

0.370

4.3

3

6

1420

YC80c-4

3/4

0.550

5.8

3

6

1430

YC90s-4

1

0.750

7.13

3

6.5

1440

YC90L-4

1.5

1.1

9.82

3

6.5

1450

YC100L-4

2

1.5

12.4

3

6.5

1460

YC112M-4

3

2.2

17.6

3

6.5

1470

YC132SA-4

4

3

23

1.6

6

1460

YC132SB-4

5

3.7

27

1.6

6

1460

Remarks:The tabulated values are those under rated Voltage 200V and rated frequency 50Hz.

  
 
 
 
MAIN TECHNICAL DATA    115V/60Hz

Model No.

Power rating

Current

(A)

Starting torque

Rated torque

Starting current

Rated current

Speed

HP

kw

(r.p.m)

YC80a-2

1/2

0.370

7.4

3

6.5

3410

YC80b-2

3/4

0.550

10.2

3

6.5

3430

YC80c-2

1

0.750

13.4

3

6.5

3460

YC90s-2

1.5

1.1

17.8

3

7.0

3480

YC90L-2

2

1.5

23.6

3

7.0

3500

YC100L-2

3

2.2

34.2

3

7.0

3530

YC80a-4

1/3

0.250

6.8

3

6

1690

YC80b-4

1/2

0.370

9.0

3

6

1700

YC80c-4

3/4

0.550

12.2

3

6

1710

YC90s-4

1

0.750

15.0

3

6.5

1730

YC90L-4

1.5

1.1

20.8

3

6.5

1740

YC100L-4

2

1.5

26.6

3

6.5

1750

YC112M-4

3

2.2

38

3

6.5

1765

YC132SA-4

4

3

41

1.6

6

1750

YC132SB-4

5

3.7

46

1.6

6

1750






Overall & Installation Dimensions:.

Base No.

nstallation Dimensions and Tolerance

Overall Dimensions

H

A

B

C

D

E

F

GD

G

GA

K

AD

AB

AA

BB

HA

HD

L

AC

80

80

125

100

50

19

40

6

6

15.5

21.5

10

110

157

35

130

10

200

310

160

90S

90

140

100

56

24

50

8

7

20

27

10

120

175

35

130

12

230

355

180

90L

90

140

125

56

24

50

8

7

20

27

10

120

175

35

165

12

230

385

180

100L

100

160

140

63

28

60

8

7

24

31

12

130

200

40

180

14

245

415

200

112M

112

190

140

70

28

60

8

7

24

31

12

140

240

50

190

15

270

440

224

132SA

132

216

140

89

38

80

10

8

33

41

12

150

266

50

178

18

302

470

262

132SB

132

216

140

89

38

80

10

8

33

41

12

150

266

50

178

18

302

470

262

BHorizontal type,base legged,end cover without flanged.If need mounting mode of type B5 or B35 ,please to explain on the order.

 

SERIE  SINGLE-PHASE 

DUAL-CAPACITOR  ASYNCHRONOUS  MOTOR

 

YL series single phase two value capacitor motor is designed and manufactured in accordance with state standards, with out-standing performance of starting and operation, low noise, compact dimensions, light weight, easy maintenance, etc.

These motors are widely used in air compressors. pumps , fans, refrigeration, medical instruments as well as small machines, etc, especially for occasion where only single-phase power supply is available.

Protection type:IP44 Insulation class: B Duty type: continuous running Cooling type:IC0141 Rated voltage:220V Rated frequency:50Hz

PERFORMANCE  SPECIFICATIONS

Model

Output

Current

(A)

Speed

(r/min)

Eff

£¨%£©

Power

factor

Locked rotor

Rated torque

(A)

Locked current

(A)

Pull-out

Rated torque

(KW)

(HP)

YL6312

0.18

1/4

1.46

3000

61

0.92

1.8

9

1.8

YL6322

0.25

1/3

1.96

3000

63

0.92

1.8

12

1.8

YL6314

0.12

1/6

1.06

1500

56

0.92

1.8

6

1.8

YL6324

0.18

1/4

1.53

1500

58

0.92

1.8

9

1.8

YL7112

0.37

1/2

2.73

3000

67

0.92

1.8

16

1.8

YL7122

0.55

3/4

3.88

3000

70

0.92

1.8

21

1.8

YL7114

0.25

1/3

1.99

1500

62

0.92

1.8

12

1.8

YL7124

0.37

1/2

2.81

1500

65

0.92

1.8

16

1.8

YL801-2

0.75

1

5.15

3000

72

0.92

1.8

29

1.8

YL802-2

1.1

1.5

7.02

3000

75

0.92

1.8

40

1.8

YL801-4

0.55

3/4

4.0

1500

68

0.92

1.8

21

1.8

YL802-4

0.75

1

5.22

1500

71

0.92

1.8

29

1.8

YL90S-2

1.5

2

9.44

3000

76

0.95

1.7

55

1.8

YL90L-2

2.2

3

13.7

3000

77

0.95

1.7

80

1.8

YL90S-4

1.1

1.5

7.21

1500

73

0.95

1.7

40

1.8

YL90L-4

1.5

2

9.57

1500

75

0.195

1.7

55

1.8

YL100L1-4

2.2

3

13.9

1500

76

0.95

1.7

80

1.8

YL100L2-4

3

4

18.6

1500

77

0.95

1.7

110

1.8

YL112M-4

2.2

3

13.9

1500

76

0.95

1.7

80

1.8

YL112M1-4

3

4

18.6

1500

77

0.95

1.7

110

1.8

YL112M2-4

3.75

5

23

1500

78

0.95

1.7

138

1.8

YL132SA-4

3

4

18.6

1500

77

0.95

1.7

110

1.8

YL132SB-4

3.75

5

23

1500

78

0.95

1.7

138

1.8

 

         


SERIE  SINGLE-PHASE 
DUAL-CAPACITOR  ASYNCHRONOUS  MOTOR

         
 

YL  Overall & Installation Dimensions:

Frame

Mounting dimensions

Overall dimensions

 

IMB14 , IMB34

IMB5 , IMB35

A

B

C

D

E

F

G

H

K

M

N

P

R

S

T

M

N

P

R

S

T

AB

AC

AD

AE

HD

L

80

125

100

50

19

40

6

15.5

80

10

165

130

200

0

12

3.5

165

130

200

0

12

3.5

160

165

120

11

230

340

90S

140

100

56

24

0

8

20

90

10

115

95

140

0

M8

3

165

130

200

0

12

3.5

180

185

130

130

240

370

90L

140

125

56

24

50

8

20

90

10

115

95

140

0

M8

3

165

130

200

0

12

3.5

180

185

130

130

240

400

100L

160

140

63

28

60

8

24

100

12

           

215

180

250

0

15

4

205

220

140

140

260

430