SERIES  SINGLE-PHASE  A .C .  SYNCHRONOUS

  GENERATORS

  

PERFORMANCE  SPECIFICATIONS

  Model 

Output

(KW)

Current(A)

Voltage(V)

   Pole

  Number

  Power

  Factor 

  Speed

   r.p.m.

Serics

Connection

Parallel

Connection

ST-2

2

8.7/230

17.4/115

4

1

1500

ST-3

3

13/230

26/115

ST-5

5

21.8/230

43.5/115

ST-7.5

7.5

32.6/230

65.2/115

ST-10

10

43.3/230

87/115

ST-12

12

52.2/230

104/115

ST-15

15

65.3/230

130/115

ST-20

20

87/230

174/115

      The  ST series generators are mainly designed to serve as power generating unit of small capacity which supply electricity for lighting purpose in ships as well as for household electric devices used in towns or villages.

      The construction of the generators is of drip-proof,salient pole rotating field self-excitation and constant voltage type.High quality electric magnetic and electrical materials are used in the alternator. Stator insulation is of class E(or B).Rotor insulation is of class B.

      The alternators are of harmonic wave self-excitation constant voltage system and automatic voltage control excitation constant voltage system,both of them have excellent dynamic performance,convenient and reliable in operation.These generators are excellent in appearance and easy to maintain.Dimensions are adopted according to I.E.C standards.

      The voltage of the alternator is 230V or 115V,the frequency is 50Hz.Its operation mode is of continuous duty.It can provide 60Hz and the other voltage’s generator according to necessary.

      The alternator can be coupled with a prime mover directly or through a V-belt,with 5% change of the prime mover under load variation of 0 ←→ 100%,at a voltage of 230V or 115V,50Hz or 60Hz to get a satisfactory constant-voltage performance.

 

ST SERIES  SINGLE-PHASE  A .C .  SYNCHRONOUS

  GENERATORS

 

 

We are able to make derivative products and products for special purposes according to customers require ments.

Model

Output

(KW)

           Installing dimensions

      External dimensions

Weight

 (kg)

A

B

C

D

E

F

G

H

K

a

b

h1

h

L1

L2

g

ST-2

  2

216

178

89

ø 32

80

10

27

132

12

34

250

18

385

480

270

35

65

ST-3

  3

216

178

89

ø 32

80

10

27

132

12

34

250

18

385

480

270

35

70

ST-5

  5

254

254

108

ø 38

80

10

33

160

15

50

310

25

440

580

325

41

120

ST-7.5

 7.5

254

254

108

ø 38

80

10

33

160

15

50

310

25

440

580

325

41

130

ST-10

 10

279

203

121

ø 42

110

12

37

180

15

60

339

25

480

610

365

45

140

ST-12

 12

279

203

121

ø 42

110

12

37

180

15

60

339

25

480

610

365

45

155

ST-15

 15

318

228

133

ø 48

110

14

42.5

200

19

60

378

25

540

660

400

51.5

192

ST-20

 20

318

228

133

ø 48

110

14

42.5

200

19

60

378

30

540

660

400

51.5

202

Note : If select Model “B”end cover you should write “B”on your order as ST-10B,if the “B”is not written on theorder,we will provide Model “A”for you,word “A”is unnecessary in the later such as ST-10.

 

STCSERIES  THREE-PHASE  A .C .  SYNCHRONOUS  GENERATORS

PERFORMANCE  SPECIFICATIONS

 


Model

Output

Current

(A)

Pole

number

Synchronous

Speed

(r.p.m.)

KVA

KW

STC-3

3.8

3

5.4

4

1500

STC-5

6.3

5

9

STC-7.5

9.4

7.5

13.5

STC-10

12.5

10

18.1

STC-12

15

12

21.7

STC-15

18.8

15

27.1

STC-20

25

20

36.1

STC-30

37.5

30

54.1

STC-40

50

40

72.2

STC-50

62.5

50

90.2

  The generators are to be used in town,the countryside,worksites,mountain districts and pasture lands as a electric power source for lighting purpose. It can also be used as a reserved power source for emergent case.

The generators are of dripproof with totary field type and with the adoption of harmonic excitation system,that allow your easy operation and simple maintenance.

  The generators ate of three-phase four-wire type,making use of star connection with neutral point.The rated line voltage is 400V,phase voltage 230V,frequency 50Hz,power factor 0.8(lag).It can provide 60Hz and the other voltage’s generator according to necessary.

  They can be coupled with a prime mover directly or through v-belt,making right or reverse continuous rotation at the rated speed.

  When the revolution slip of prime mover is 3% and load varies in the range of  0 ←→ 100%,cosα1.0 ←→ 0.8 they give good constant voltage.After sudden cnange (increase or decrease)of load,the generators will soon return to their normal working state.

  Without any starting devices the generator can directly start an unloaded squirrel cage induction motor.

 

 

STCSERIES  THREE-PHASE  A .C .  SYNCHRONOUS  GENERATORS

 

 

We are able to make derivative products and products for special purposes according to customers require ments.

 Model

Output

Installing dimensions

External dimensions

Weight

 (kg)

KVA

KW

A

B

C

D

E

F

G

H

K

a

b

h1

h

L1

L2

g

STC-3

3.8

3

216

178

89

ø 32

80

10

26.8

132

13

34

250

18

400

480

270

34.8

 70

STC-5

6.3

5

254

254

108

ø 38

80

12

32.8

160

16

50

310

25

450

580

325

40.8

120

STC-7.5

9.4

7.5

254

254

108

ø 38

80

12

32.8

160

16

50

310

25

450

580

325

40.8

 130

STC-10

12.5

10

279

203

121

ø 42

110

12

36.8

180

16

60

339

25

490

610

365

44.8

140

STC-12

15

12

279

203

121

ø 42

110

12

36.8

180

16

60

339

25

490

610

365

44.8

155

STC-15

18.8

15

318

228

133

ø 48

110

14

42.2

200

20

60

378

30

500

660

400

51.2

192

STC-20

25

20

318

228

133

ø 48

110

14

42.2

200

20

60

378

30

500

660

400

51.2

202

STC-30

37.5

30

356

286

149

ø 60

140

18

53

225

20

65

421

32

650

770

452

64

257

STC-40

50

40

356

286

149

ø 60

140

18

53

225

20

65

421

32

650

770

452

64

290

STC-50

62.5

50

356

311

149

ø 60

140

18

53

225

20

65

421

32

650

810

452

64

344

Note: If select Model “B”end cover you should write “B”on your order as ST-10B,if the “B”is not written on theorder,we will provide Model “A”for you,word “A”is unnecessary in the later such as ST-10.