DZ47 (C45N) Mini Circuit Breaker
DZ47 (C45N) series circuit breaker is used in lighting distrbution system or motor distribution system for portecting overload and short-circuit in the system. The product is novel in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly and its easy installation uses with guide. Its case and items are adopted by high fire-resistant and shockproof plastics. This product, with long life, is mainly used in AC 50Hz/60Hz single-pole 240V or two, three, four-pole 415V circuit for overload and short-circuit protecion as well as for unfrequent on-and-off switching of electric equipment and lighting circuit under normal condition. The products comply with IEC 898 & BS 3871.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DZ47 (C45N) |
|||||||||||||||||||
|
Standard |
BS 3871-1 IEC898 |
IEC 157-1 |
|||||||||||||||||
|
Rated current (A) |
1 to 40 50 to 60 |
50 to 60 |
1 |
3 |
10 to 40 |
50 |
60 |
||||||||||||
|
Pole No. |
1 |
2 3 4 |
1 |
2 3 4 |
1 |
2 3 4 |
2 3 4 |
1 |
2 3 4 |
2 3 4 |
1 |
2 3 4 |
2 3 4 |
1 |
2 3 4 |
2 3 4 |
1 |
2 3 4 |
2 3 4 |
|
Voltage (V) |
240 |
415 |
240 |
415 |
220 240 |
220 240 |
380 415 |
220 240 |
220 240 |
380 415 |
220 240 |
220 240 |
380 410 |
220 240 |
220 240 |
380 410 |
220 240 |
220 240 |
380 410 |
|
Breaking capacity (A) |
6000 |
6000 |
4000 |
4000 |
1000 |
2000 |
1000 |
8000 |
2000 |
8000 |
7000 |
16000 |
8000 |
6000 |
10000 |
6000 |
5000 |
10000 |
5000 |
BHP series miniature circuit breaker has small size, light weight,
novel structure and excellent performance. They are mounted in the illuminating
distribution board and used in guesthouses, block of flats, high buildings,
squares, airports, railway stations, plants and enterprises etc, in
AC circuits 240V(single pole) up to 415V (3pole)50Hz for protection
of overload, short circuit and for circuit change-over in lighting system.
Breaking capacity is 3 KA. The items comply with BS & NEMA standard.
|
Rated Current (A) |
Poles No (P) |
Rated Voltage (V) |
Breaking capacity (KA) |
Setting temperature of protective characteristics |
|
|
B.S |
NEMA |
||||
|
6,10,15, 20,30, 40,50,60 |
1P 2P |
AC12 |
5 |
40℃ |
|
|
AC120/240 |
5 |
||||
|
AC240/415 |
3 |
||||
|
AC120/240 |
40℃ |
||||
|
AC240/415 |
3 |
5 |
|||
|
3P |
AC240/415 |
3 |
|||
|
BHP-S M6 |
6 |
40℃ |
|||
S060 Mini Circuit Breaker

The products are suitable for overload and short circuit protection in the circuit of AC 50/60Hz, rated voltage of single pole up to 240V, two or three poles up to 415V and rated currdnt up to 60A. It can also be used for and unfrequent switchover of the circuit and illumination under normal condition.
|
Rated Frequency |
50/60Hz |
|
Rated Voltage |
240/415V AC |
|
Rated Breaking capacity |
300A |
|
Rated Frame Current |
40A |
|
Rated Trip Current |
2,4,6,10,20,25,32,40A |
|
Pole No. |
1P,2P,3P, |
|
W40 Mini Circuit Brealer
W40 series miniature circuit breaker has characteristics of small size, light weight, novel structure and excellent performance. They are mounted in the illumination board and used in guesthouses, block of flats high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V (single-pole), up to 415V (2,3-pole) 50Hz for overload and short circuit protection and for circuit changeover in lighting system. Breaking capacity is 3KA. Its indicator can be used as circuit indication in illumination and industry system. Specifications
Specifications
Specifications
C60N Mini Circuit Breaker
Specifications
S101 Screw Circuit Breaker
Specifications
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NFIN Earth Leakage Circuit Breaker
The earth leakage circuit breaks (RCB)NFIN is in conformity with the standards of VDE 0664, CEE 27 and BS 4293. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus it is suitable to avoid the shock hazard and fire caused by earth leakage. NFIN RCB is mainly suitable for using in variety of plants, enterprises, buildings, constructions, commerce, guesthouses and families. It can be used in circuits up to single phase 240V, three phase 415V, 50Hz or 60Hz. Specifications
The earth leakage circuit breakers type FIN is in conformity with the standards of VDE 0664, CEE 27 and BS 4293. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus it is suitable to avoid the shock hazard and fire caused by earth leakage. NFIN ELCB is mainly suitable for using in variety of plants, enterprises, buildings, constructions, commerce, guesthouses and families. It can be used in circuits up to single phase 240V, three phase 415V, 50Hz or 60Hz. Specifications
DZ47L (C45L) Earth Leakage Circuit Breaker
Specifications
M611 Motor Protection Circuit Breaker
This product includes basic type switch and 26 accessories with purposes of expanding usage. It complies with standards of IEC 157-1 & VDE0660,etc. Specifications
3VE Motor Protection Circuit Breaker
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type |
3VE1 |
3VE3 |
3VE4 |
|
|
Poles |
3 |
3 |
||
|
Rated current (A) |
20 |
32 |
3 |
|
|
Rated Voltage (V) |
660 |
660 |
63 |
|
|
Rated insulation voltage (V) |
660V |
750 |
75660 |
|
|
Current setting range (A) |
0.1-0.16 0.16-0.25 0.25-0.4 0.4-0.63 0.63-1.1-1.6 1.6-2.5 2-3.2 2.5-4 3.2-5 4-6.3 5-8 6.3-10 8-12.5 10-16 14-20 |
1-1.6 1.6-2.5 2.5-4 4-6.3 6.3-10 8-12.5 10-16 12.5-20 16-25 22-32 |
6.3-10 10-16 16-25 22-32 28-40 36-50 45-63 |
|
|
Power of controlled motor (KW) |
220V |
5.5 |
9 |
18 |
|
380V |
10 |
16 |
32 |
|
|
660V |
13 |
26 |
58 |
|
|
Mechanical life (1x106) |
10 |
10 |
3 |
|
|
Protective feature |
220V |
Not act within 2hrs |
||
|
380V |
Act within 2hrs |
|||
|
660V |
Action snap |
|||
|
RDM7 (EA,SA) series Moulded Case Circuit Breaker It is suitable for shipping and land ,in the circuit with AC 50 or 60Hz, rated insulation voltage 660V, DC voltage 250V or less, rated current from 3A to 1200A, used for making and breaking circuit unfrequently, and protecting circuit against over load short circuit. SA Specifications
EA Specifications